certifiedmark600.jpgsupport_statement_seal_1200.jpg

cof firemarshal letter small.jpg

Fire Marshal letter small.jpg

vista128fb_pr.jpg

Designed to integrate seamlessly with CCTV, access control and Honeywell’s full range of fire and burglary components, the VISTA-128FB provides the ultimate protection of life and property. The UL listed Commercial Fire and Burglary Control Platform controls up to eight partitions and supports up to 128 zones/points using hardwired, wireless and addressable V-Plex® technologies.

A diverse line of Honeywell initiating devices, notification circuits, digital dialers, keypads, RF receivers and relays support this extremely powerful control platform. The VISTA-128FB has been designed to mount quickly and easily in an attack resistant cabinet and is available in 12V and 24V models.

 

FEATURES

  • Supports addressable V-Plex access control points using VistaKey (1 to 8 doors)
  • Supports up to 15 doors of access control using VISTA Gateway Module (VGM)*
  • Supports CCTV applications with the new VistaView-100 CCTV switcher module
  • Identifies the point or zone of a fire or alarm, using the new FSA-8/FSA-24 Fire system annunciator
  • Stores up to 512 events and can accommodate 150 user codes
  • New E2 software simplifies programming
  • Easily programmed and maintained with newly upgraded Compass Downloader software
  • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones
  • Can control eight separate areas independently (8 partitions)
  • Two on-board notification (bell) circuits delivering 2.3A @ 12V or 3.4 amp @ 24V
  • Automatic smoke detector sensitivity maintenance testing

* Connects to Honeywell's Passpoint Access Control Systems. Maximum 32 doors.

 

 

5140mps1_pr.jpgManual Pull Station

  • Aluminum die cast
  • Key reset and test
  • Screw terminals
  • Gold contact SPST
  • ADA compliant
  • UL, CSFM, MEA listed and approved

 

 

5192sdt_pr.jpg

The Honeywell 5192 Series low profile, addressable V-Plex® smoke detectors deliver state-of-the-art features and benefits in a cost-effective package. These detectors are designed to provide open area coverage and are compatible with Honeywell’s VISTA controls supporting V-Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range.

An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability – a feature normally found in today’s high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the control, via the V-Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 40, 50P, 100-24 and FAP FA1600C, FA1660C and FA1700C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability. Another important benefit of these V-Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials!

Features

  • Low profile design
  • V-Plex addressable loop device
  • Automatic maintenance reporting
  • Available with integral heat sensor
  • Simple 2 wire installation
  • DIP switch or serial number programmable
  • Lines on existing or conventional wiring